| Time-resolved MS, m/z = 44 (CO₂), PCO = 1 × 10⁻⁵ mbar, PO₂ = 1 × 10⁻⁵ or 5 × 10⁻⁵ mbar, 425–500 K, 5 s CO-on and 11 s CO-off intervals, average of 110 cycles | For both O₂ pressures, a primary CO₂ production peak appeared immediately after the valve opened, followed by a decrease in CO₂ production, and a secondary CO₂ production peak appeared after the valve closed. At 1 × 10⁻⁵ mbar O₂, the initial peak was of similar magnitude at all four temperatures; the steady-state CO₂ production rate increased with temperature; higher steady-state rates led to higher secondary peaks; and the second peak shifted to later times as temperature decreased. At 5 × 10⁻⁵ mbar O₂, all CO₂ production rates increased; the first-peak increase was more prominent at lower temperatures; and all secondary peaks shifted to earlier times while retaining the same temperature ordering |
|---|---|
| Time-resolved IRRAS, PCO = 1 × 10⁻⁵ mbar, PO₂ = 1 × 10⁻⁵ or 5 × 10⁻⁵ mbar, 425–500 K, 5 s CO-on and 11 s CO-off intervals, average of 110 cycles | The full 2020–2160 cm⁻¹ spectral region showed buildup of the linearly bound CO band during CO exposure and its disappearance after valve closure; depletion became faster as either temperature or O₂ pressure increased. The CO stretching region was typically integrated over 2030–2140 cm⁻¹ |
| Work function, 473 K | The measured work function of clean Pt(111) was 6.32 ± 0.05 eV. Using 6.10 eV as the clean-Pt(111) reference, a common correction of −0.22 eV was applied to all reported values. The corrected work function was 5.47 ± 0.05 eV under approximately 1 × 10⁻⁷ Torr CO and 5.77 ± 0.05 eV under approximately 1 × 10⁻⁷ Torr O₂ |
| Work function, CO:O₂ = 1:22.4, O₂ feed fraction = 0.957, PO₂ = 1.12 × 10⁻⁷ Torr, 473 K | 5.68 eV |
| Work function, CO:O₂ = 1:7.0, O₂ feed fraction = 0.875, PO₂ = 1.12 × 10⁻⁷ Torr, 473 K | 5.64 eV |
| Work function, CO:O₂ = 1:4.8, O₂ feed fraction = 0.828, PO₂ = 1.12 × 10⁻⁷ Torr, 473 K | 5.58 eV |
| Work function, CO:O₂ = 1:37.3, O₂ feed fraction = 0.974, PO₂ = 1.12 × 10⁻⁷ Torr, 473 K | 5.68 eV |
| Work function, CO:O₂ = 1:14.0, O₂ feed fraction = 0.933, PO₂ = 1.12 × 10⁻⁸ Torr, 473 K | 5.62 eV |
| Work function, CO:O₂ = 1:1.2, O₂ feed fraction = 0.545, PO₂ = 1.12 × 10⁻⁸ Torr, 473 K | 5.58 eV |
| Work function, CO:O₂ = 4.4:1, O₂ feed fraction = 0.185, PO₂ = 1.12 × 10⁻⁸ Torr, 473 K | 5.54 eV |
| Work function, CO:O₂ = 10:1, O₂ feed fraction = 0.091, PO₂ = 1.12 × 10⁻⁸ Torr, 473 K | 5.51 eV |
Esteban L. Fornero, Eliseo Perez Gomez, Gengnan Li, Zubin Darbari, Cailey Bobadilla, Jerzy Sadowski, Qin Wu, J. Anibal Boscoboinik. “Dynamic reactant forcing circumvents CO poisoning in catalytic CO oxidation.” ChemRxiv (). https://doi.org/10.26434/chemrxiv.15007905/v1
Values presented only in spectra, time traces, maps, or other plots or images were not transcribed
| Time-resolved MS, m/z = 44, CO/O₂ pulsing protocol | A small background response and no pronounced dual-peak structure were observed |
|---|
| IRRAS, 450 K, pulsing-valve and continuous CO dosing | The spectrum obtained with the pulsing valve at an ion-gauge reading of 1 × 10⁻⁵ mbar closely matched the continuous-dose spectrum at 1 × 10⁻⁵ mbar in peak position, approximately 1874 cm⁻¹, and absorbance |
|---|